Step | | Procedure & Parts & Tools |
1 |
|
TURN THE LOCKING CAP TO REMOVE IT FROM THE MACHINE AND DRAIN THE TANK.
|
2 |
|
LAY MACHINE DOWN WITH THE BACK COVER FACING UP. REMOVE THE TANK SCREW.
Screwdriver-phillips |
|
|
3 |
|
FLIP THE MACHINE OVER SO THE FRONT COVER IS FACING UP.REST THE MACHINE ON BOARDS SO THAT THE FILTER ON THE BACK DOESNT GET BROKEN.
|
4 |
|
REMOVE THE 4 SCREWS AND LIFT UP ON THE FRONT COVER TO REMOVE IT.
Screwdriver-phillips |
|
|
5 |
|
LOCATE THE COMPRESSOR AT THE BOTTOM OF THE MACHINE.
|
6 |
|
HOLD THE 3 SCREWS IN PLACE WITH YOUR HAND AND TURN THE NUT DRIVER TO REMOVE THE SCREWS.
Nut driver-metric 7mm |
|
|
7 |
|
LOCATE THE 2 WHITE WIRES FROM THE COMPRESSOR TO THE WHITE TERMINAL BLOCK. PULL UP ON THE WIRES TO REMOVE THEM.
|
8 |
|
PULL THE COMPRESSOR HOSE TO DISCONNECT IT FROM THE COMPRESSOR. REMOVE THE COMPRESSOR FROM THE MACHINE.
|
9 |
|
PULL THE 2 WIRE CONNECTORS FROM THE SOLENOID VALVE.
|
10 |
|
PUSH IN ON THE HOSE CONNECTOR COLLAR AND PULL THE HOSE OUT TO REMOVE IT FROM THE SOLENOID VALVE.
|
11 |
|
LOCATE THE YELLOW SOLUTION FILTER CAP ON THE BACK OF THE MACHINE AND TURN IT.
|
12 |
|
PULL TO REMOVE THE SOLUTION FILTER.
|
13 |
|
REMOVE THE 2 SCREWS HOLDING THE FILTER HOUSING.
Screwdriver-phillips |
|
|
14 |
|
ON THE INSIDE OF THE MACHINE, PULL THE SOLUTION FILTER HOUSING OUT OF THE MACHINE.
|
15 |
|
REMOVE THE 2 SCREWS TO REMOVE THE HOSE FITTING.
Screwdriver-phillips |
|
|
16 |
|
IF GASKETS ARE NOT CRACKED OR TORN, SET THEM BOTH ASIDE TO REUSE ON THE NEW SOLENOID VALVE.
|
17 |
|
REMOVE THE 2 SCREWS TO REMOVE THE FILTER HOUSING FROM THE SOLENOID VALVE.
Screwdriver-phillips |
|
|
18 |
|
IF GASKETS ARE NOT CRACKED OR TORN, SET THEM BOTH ASIDE TO REUSE ON THE NEW SOLENOID VALVE.
|
19 |
|
REVERSE STEPS 1 THRU 18 TO INSTALL A NEW SOLENOID VALVE. REPLACE THE GASKETS IF NEEDED.
|